Home Developers Evidence electrical.mosfet.total_loss

Public evidence

electrical.mosfet.total_loss

Machine-checked verification for calculation version 1.1.2 · tier internally_reviewed

CVP status

CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance

Composite conduction+switching; gate/Qrr excluded from device Tj path

Declared partition coverage
PASS · 4/4 declared partitions (on_interval_rms, dc, with-optional-terms, invalid-domain)
Versions
Calculation 1.1.2 · CVP protocol 1.0.0-proposed · Evidence 2026-10-28.meta-metrics-v2
Verification revision
2026-10-28.meta-metrics-v2 · 8/8 property · digest 12ea603c0107

Verification

Legacy regression suite: 39/39 calculation tests · Production surface contract 20/20

Three distinct suites: educational examples on the calculator page, this legacy regression count (39/39 golden + boundary), and the CVP verification suite below. They are not the same number. Property, metamorphic, round-trip, O3, and interface statuses/checks are recorded in the CVP Manifest . SKIP (0/0) means that suite has no published vectors.

    This calculator CURRENT · Public schema 1.1.2 matches · Semantic contract ✓ · Production attested · Public/cache ✓ · Origin ✓

CVP verification suite

Protocol checks from the Evidence Manifest. Distinct from the legacy regression suite above. Verification revision 2026-10-28.meta-metrics-v2. Calculation version 1.1.2. CVP 1.0.0-proposed. 3/3 golden · 19/19 CVP boundary · 19/19 invalid · 8/8 property · 2/2 metamorphic · 1/1 cross-interface · 20/20 CVP contract. digest 12ea603c0107.

  • Golden (oracle-backed) 3 / 3
  • CVP boundary 19 / 19
  • Invalid input 19 / 19
  • Property 8 / 8
  • Metamorphic 2 / 2
  • Cross-interface 1 / 1
  • CVP contract 20 / 20
  • Interfaces PASS · UI (SSR) / REST / MCP
  • Interface claim ui-ssr is query-result HTML, not a live browser session.
  • Assurance Engineering
  • contract page version PASS
  • contract capability version PASS
  • contract input schema version PASS
  • contract output schema version PASS
  • evidence version matches manifest PASS
  • schema output required declared PASS
  • schema valid input executes PASS
  • engine success output validates schema PASS
  • schema rejects incomplete input PASS
  • temperature linear schema requires Tj_C PASS
  • temperature ratio schema requires rds_ratio PASS
  • share url roundtrip dc PASS
  • share url roundtrip pwm PASS
  • qg xor vdrive rejected PASS
  • schema rejects qg without vdrive PASS
  • schema rejects incomplete coss mode PASS
  • device excludes gate qrr PASS
  • omitted terms listed PASS
  • eoss overrides coss PASS
  • rest success payload validates schema PASS

Fingerprint sha256:63796283361c5a2cc011efc022665fc2401eee8cd2aa34530424d3f8836e4702

Input schema sha256:cd71e7633305576f0635af201a746a518b735993cc5a997b458ad543f4ed3b05 · Output schema sha256:1905f96b840a7a6cc79298022264e09a3c9031a1276ed4686145711363dbfe16 · Build-time SHA-256 digests prove published artifacts agree with each other (release_integrity.scope=workspace). Production attestation GETs canonical URLs twice (public/cached view and origin), including Capability HTML, via npm run attest:production --write (published at /.well-known/calculatorx-production-attestation.json) and fails if the public Capability page advertises a different calculation_version. This is artifact consistency, not an independent immutable release log.

Build & scope

Engine identity and declared limitations.

Tool
mosfet-total-loss
Engine
mosfet-total-loss
Engine build
2026-09-10
Evidence core
2026-09-05T02:35:39.217Z
Rendered
2026-11-10T05:18:41.728Z
Last reviewed
2026-08-19

Assumptions

  • Hard-switching linear V/I overlap.
  • Conduction current_basis contract is identical to electrical.mosfet.conduction_loss.
  • Coss term is lumped or Eoss-at-Vds — not a Qoss(V) integral.
  • P_gate is drive-circuit power, not die dissipation.
  • P_rr is commutation loss, usually not this MOSFET.
  • Tj_est is steady-state RthJA of P_device only.

Limitations

  • First-order hard-switching workspace — not Eon/Eoff tables, Qoss(V) curves, or compact models
  • Conduction uses electrical.mosfet.conduction_loss; switching/gate use electrical.mosfet.switching_loss
  • Default α = 0.006 /°C is a Si planning default, not manufacturer validated
  • P_coss from ½·Coss·V²·f is a lumped equivalent — prefer datasheet Eoss at Vds
  • Overlap P_sw plus P_coss may overestimate due to double counting; first-order only — validate against measured Eon/Eoff
  • P_rr = Qrr·Vds·f is recovered-charge commutation loss, usually attributed to the complementary switch — not this die
  • P_gate is gate-drive power (driver + Rg + Rg,int) — not MOSFET junction dissipation; Tj_est uses P_device only
  • Tj_est is steady-state RthJA only — not Zth or CFD
  • Numeric 0 on omitted P_gate/P_coss/P_rr means not included (see terms_omitted), not a measured zero
  • Optional Qg/Coss/Eoss/Qrr if present must be > 0; explicit 0 is not yet a supported known-zero state
  • Qg and Vdrive must both be present or both omitted (else NEEDS_TWO_INPUTS)

Sources

Standards and references supporting this tool specification. Methods are listed separately — they are algorithms, not bibliographic sources.

Verification disclosure

Aggregate outcomes, scope and artifact commitments are public. Complete test inputs, expected values, execution records and oracle infrastructure are retained privately. This summary does not independently reproduce the full verification run.