Home Developers Evidence physics.thermo.composite_wall

Public evidence

physics.thermo.composite_wall

Machine-checked verification for calculation version 1.0.0 · tier engine_tested

CVP status

CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance · Plane wall R = Σ L_i/(k_i A), optional films 1/(h A), optional Q = ΔT/R, + O3 mpmath tabulated resistance.

Not cylindrical. O3 tabulated vectors only.

Declared partition coverage
PASS · 7/7 declared partitions (films, alias, layers, heat, awkward, default, invalid-domain)
Versions
Calculation 1.0.0 · CVP protocol 1.0.0-proposed · Evidence 2026-09-25.o2-o3
Verification revision
2026-09-25.o2-o3 · 1/1 property · digest d63c309b6b4c

Verification

Legacy regression suite: 14/14 calculation tests · Production surface contract 6/6

Three distinct suites: educational examples on the calculator page, this legacy regression count (14/14 golden + boundary), and the CVP verification suite below. They are not the same number. Property, metamorphic, round-trip, O3, and interface statuses/checks are recorded in the CVP Manifest . SKIP (0/0) means that suite has no published vectors.

    This calculator CURRENT · Public schema 1.0.0 matches · Semantic contract ✓ · Production attested · Public/cache ✓ · Origin ✓

CVP verification suite

Protocol checks from the Evidence Manifest. Distinct from the legacy regression suite above. Verification revision 2026-09-25.o2-o3. Calculation version 1.0.0. CVP 1.0.0-proposed. 3/3 golden · 7/7 CVP boundary · 7/7 invalid · 1/1 property · 1/1 metamorphic · 8/8 O3 · 2/2 cross-interface · 6/6 CVP contract. digest d63c309b6b4c. O2: plane composite wall vs a separate-module identity (≤2 ULP). Not a lumped R-network and not cylindrical. ≤2 ULP vs O3 applies only to the published tabulated composite-wall vectors. Not radiation and not a heatsink.

  • Golden (oracle-backed) 3 / 3
  • CVP boundary 7 / 7
  • Invalid input 7 / 7
  • Property 1 / 1
  • Metamorphic 1 / 1
  • O3 high-precision 8 / 8
  • Cross-interface 2 / 2
  • CVP contract 6 / 6
  • Interfaces PASS · UI (SSR) / REST / MCP
  • Interface claim ui-ssr is query-result HTML, not a live browser session. Error-path engine·REST·MCP 1/1 (status, code, calculation_version). SSR compared on URL-canonical requested calculations; empty query is idle (not an error) and JSON-typed object/array inputs are REST/MCP-only.
  • Verified scope Plane wall R = Σ L_i/(k_i A), optional films 1/(h A), optional Q = ΔT/R, + O3 mpmath tabulated resistance.
  • Assurance Engineering
  • Deferred Not a lumped R-network, not cylindrical, and not radiation.
  • release artifacts aligned PASS
  • schema output required declared PASS
  • schema valid input executes PASS
  • engine success output validates schema PASS
  • schema rejects incomplete input PASS
  • rest success payload validates schema PASS

Fingerprint sha256:7832177001854ed16e851ba103e5917f90bfcec7dbc24861b6ecfe5911e008d3

Input schema sha256:5047588b25f9c00388cc4d53cd92168749c055d21833c428a8ae48d4a92143a4 · Output schema sha256:c6d08b24bee10c6ea8371bf251adccc275d7ba81b306c9a374d5a5a0de5f6666 · Build-time SHA-256 digests prove published artifacts agree with each other (release_integrity.scope=workspace). Production attestation GETs canonical URLs twice (public/cached view and origin), including Capability HTML, via npm run attest:production --write (published at /.well-known/calculatorx-production-attestation.json) and fails if the public Capability page advertises a different calculation_version. This is artifact consistency, not an independent immutable release log.

Build & scope

Engine identity and declared limitations.

Tool
composite-wall
Engine
composite-wall
Engine build
2026-09-17
Evidence core
2026-09-17T02:06:15.504Z
Rendered
2026-11-10T05:18:42.005Z
Last reviewed
—

Assumptions

  • Plane composite wall; 1-D; shared A; R_i = L_i/(k_i A)
  • Optional films R = 1/(h A); series only; Q=ΔT/R
  • Not Fourier/Newton Q pages
  • Not lumped R-network, not heatsink θ, not steam, not cylindrical

Limitations

  • Plane wall; 1-D; shared A; SI K/W
  • R_i = L_i/(k_i A); optional films 1/(h A); Q=ΔT/R when ΔT is given
  • Not Fourier/Newton Q (see /calc/physics/heat-transfer)
  • Not lumped R-network (see /calc/physics/thermal-resistance)
  • Not heatsink θJC/θSA, not steam, not cylindrical

Sources

Standards and references supporting this tool specification. Methods are listed separately — they are algorithms, not bibliographic sources.

Verification disclosure

Aggregate outcomes, scope and artifact commitments are public. Complete test inputs, expected values, execution records and oracle infrastructure are retained privately. This summary does not independently reproduce the full verification run.