Home Developers Evidence physics.fluid.venturi

Public evidence

physics.fluid.venturi

Machine-checked verification for calculation version 1.0.0 · tier engine_tested

CVP status

CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance · Q = Cd E A2 sqrt(2 Δp/ρ), E = 1/sqrt(1−β^4), default Cd = 0.98, plus pressure, throat, and Cd solves, + O3 mpmath tabulated discharge.

Not an orifice wrap. O3 tabulated vectors only.

Declared partition coverage
PASS · 5/5 declared partitions (flow, solve, given-cd, awkward, invalid-domain)
Versions
Calculation 1.0.0 · CVP protocol 1.0.0-proposed · Evidence 2026-09-25.o2-o3
Verification revision
2026-09-25.o2-o3 · 1/1 property · digest a4f2e3873621

Verification

Legacy regression suite: 17/17 calculation tests · Production surface contract 6/6

Three distinct suites: educational examples on the calculator page, this legacy regression count (17/17 golden + boundary), and the CVP verification suite below. They are not the same number. Property, metamorphic, round-trip, O3, and interface statuses/checks are recorded in the CVP Manifest . SKIP (0/0) means that suite has no published vectors.

    This calculator CURRENT · Public schema 1.0.0 matches · Semantic contract ✓ · Production attested · Public/cache ✓ · Origin ✓

CVP verification suite

Protocol checks from the Evidence Manifest. Distinct from the legacy regression suite above. Verification revision 2026-09-25.o2-o3. Calculation version 1.0.0. CVP 1.0.0-proposed. 4/4 golden · 9/9 CVP boundary · 9/9 invalid · 1/1 property · 1/1 metamorphic · 8/8 O3 · 2/2 cross-interface · 6/6 CVP contract. digest a4f2e3873621. O2: venturi meter vs a separate-module identity (≤2 ULP). Not an orifice wrap, not Q=Av, and not Darcy. ≤2 ULP vs O3 applies only to the published tabulated venturi vectors. Not Q=Av, not Manning, and not Darcy.

  • Golden (oracle-backed) 4 / 4
  • CVP boundary 9 / 9
  • Invalid input 9 / 9
  • Property 1 / 1
  • Metamorphic 1 / 1
  • O3 high-precision 8 / 8
  • Cross-interface 2 / 2
  • CVP contract 6 / 6
  • Interfaces PASS · UI (SSR) / REST / MCP
  • Interface claim ui-ssr is query-result HTML, not a live browser session. Error-path engine·REST·MCP 1/1 (status, code, calculation_version). SSR compared on URL-canonical requested calculations; empty query is idle (not an error) and JSON-typed object/array inputs are REST/MCP-only.
  • Verified scope Q = Cd E A2 sqrt(2 Δp/ρ), E = 1/sqrt(1−β^4), default Cd = 0.98, plus pressure, throat, and Cd solves, + O3 mpmath tabulated discharge.
  • Assurance Engineering
  • Deferred Not an orifice wrap, not Q=Av, and not Darcy.
  • release artifacts aligned PASS
  • schema output required declared PASS
  • schema valid input executes PASS
  • engine success output validates schema PASS
  • schema rejects incomplete input PASS
  • rest success payload validates schema PASS

Fingerprint sha256:a8883abb131362b9a281b5c4790a515f8c17b6890ef76f0040c477af31316db2

Input schema sha256:c4da2ae37ad4ee5e90b9bbaf74312fe153c1c329d3f98a66377ac11f4d52e539 · Output schema sha256:6026cf5a2c5ebcdb14abe4f7f002bc1233ea273c3230da7855d0ad4bd663665c · Build-time SHA-256 digests prove published artifacts agree with each other (release_integrity.scope=workspace). Production attestation GETs canonical URLs twice (public/cached view and origin), including Capability HTML, via npm run attest:production --write (published at /.well-known/calculatorx-production-attestation.json) and fails if the public Capability page advertises a different calculation_version. This is artifact consistency, not an independent immutable release log.

Build & scope

Engine identity and declared limitations.

Tool
venturi
Engine
venturi
Engine build
2026-09-17
Evidence core
2026-09-17T05:19:25.805Z
Rendered
2026-11-10T05:18:41.932Z
Last reviewed
—

Assumptions

  • Incompressible venturi tube; SI; default C_d=0.98; C_d in (0, 1]
  • Q=C_d A2 √(2Δp/(ρ(1−β⁴))), β=D2/D1; Q_ideal uses C_d=1
  • Optional same-fluid manometer Δh with Δp=ρ g Δh; not tank H
  • Not an orifice plate, not Q=Av, not Darcy, not minor-loss K, not valve Cv/Kv

Limitations

  • Incompressible venturi: Q = C_d A2 √(2Δp/(ρ(1−β⁴))), β=D2/D1; default C_d=0.98
  • Ideal Bernoulli Q_ideal uses C_d=1; optional same-fluid manometer Δh, Δp=ρ g Δh
  • Not an orifice plate, not Q=Av, not Darcy, not minor-loss K, not valve Cv/Kv

Sources

Standards and references supporting this tool specification. Methods are listed separately — they are algorithms, not bibliographic sources.

Verification disclosure

Aggregate outcomes, scope and artifact commitments are public. Complete test inputs, expected values, execution records and oracle infrastructure are retained privately. This summary does not independently reproduce the full verification run.