Home Developers Evidence physics.fluid.valve_cv

Public evidence

physics.fluid.valve_cv

Machine-checked verification for calculation version 1.0.0 · tier engine_tested

CVP status

CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance · Q_m³/h = Kv √(Δp_bar/SG), Kv = 0.865 Cv, plus pressure, Kv, and Cv solves, + O3 mpmath tabulated flow.

Not a venturi. O3 tabulated vectors only.

Declared partition coverage
PASS · 5/5 declared partitions (flow, cv, solve, awkward, invalid-domain)
Versions
Calculation 1.0.0 · CVP protocol 1.0.0-proposed · Evidence 2026-09-25.o2-o3
Verification revision
2026-09-25.o2-o3 · 1/1 property · digest e7be7b65192a

Verification

Legacy regression suite: 17/17 calculation tests · Production surface contract 5/5

Three distinct suites: educational examples on the calculator page, this legacy regression count (17/17 golden + boundary), and the CVP verification suite below. They are not the same number. Property, metamorphic, round-trip, O3, and interface statuses/checks are recorded in the CVP Manifest . SKIP (0/0) means that suite has no published vectors.

    This calculator CURRENT · Public schema 1.0.0 matches · Semantic contract ✓ · Production attested · Public/cache ✓ · Origin ✓

CVP verification suite

Protocol checks from the Evidence Manifest. Distinct from the legacy regression suite above. Verification revision 2026-09-25.o2-o3. Calculation version 1.0.0. CVP 1.0.0-proposed. 4/4 golden · 9/9 CVP boundary · 9/9 invalid · 1/1 property · 1/1 metamorphic · 8/8 O3 · 2/2 cross-interface · 5/5 CVP contract. digest e7be7b65192a. O2: valve Kv/Cv vs a separate-module identity (≤2 ULP). Not a venturi wrap, not an orifice, and not Q=Av. ≤2 ULP vs O3 applies only to the published tabulated venturi vectors. Not Q=Av, not Manning, and not Darcy.

  • Golden (oracle-backed) 4 / 4
  • CVP boundary 9 / 9
  • Invalid input 9 / 9
  • Property 1 / 1
  • Metamorphic 1 / 1
  • O3 high-precision 8 / 8
  • Cross-interface 2 / 2
  • CVP contract 5 / 5
  • Interfaces PASS · UI (SSR) / REST / MCP
  • Interface claim ui-ssr is query-result HTML, not a live browser session. Error-path engine·REST·MCP 1/1 (status, code, calculation_version). SSR compared on URL-canonical requested calculations; empty query is idle (not an error) and JSON-typed object/array inputs are REST/MCP-only.
  • Verified scope Q_m³/h = Kv √(Δp_bar/SG), Kv = 0.865 Cv, plus pressure, Kv, and Cv solves, + O3 mpmath tabulated flow.
  • Assurance Engineering
  • Deferred Not a venturi wrap, not an orifice, and not Q=Av.
  • release artifacts aligned PASS
  • schema output required declared PASS
  • schema valid input executes PASS
  • engine success output validates schema PASS
  • rest success payload validates schema PASS

Fingerprint sha256:d4789ab3e4028776421f6e45c57d69b7d91e268116dfb37f88d6b000b21bcec7

Input schema sha256:d38cd4dee167c35753ba3e0e80283228a6156ce20f1427cfb683c53a4380dcf4 · Output schema sha256:c10b35f24095413db98c2410feefd666b46121f52b69ec7e99fa3ae235b5a7f2 · Build-time SHA-256 digests prove published artifacts agree with each other (release_integrity.scope=workspace). Production attestation GETs canonical URLs twice (public/cached view and origin), including Capability HTML, via npm run attest:production --write (published at /.well-known/calculatorx-production-attestation.json) and fails if the public Capability page advertises a different calculation_version. This is artifact consistency, not an independent immutable release log.

Build & scope

Engine identity and declared limitations.

Tool
valve-flow-coefficient
Engine
valve-flow-coefficient
Engine build
2026-09-17
Evidence core
2026-09-17T05:39:40.082Z
Rendered
2026-11-10T05:18:41.933Z
Last reviewed
—

Assumptions

  • Incompressible liquid; Q_m³/h = Kv √(Δp_bar/SG); default SG=1
  • Kv = 0.865 Cv (IEC 60534-1); frozen, not a US-gpm engine
  • Not gas, not choked, not IEC 60534-2-1 xT/Y
  • Not a venturi, not an orifice, not Q=Av, not Darcy, not minor-loss K

Limitations

  • Incompressible liquid valve: Q_m³/h = Kv √(Δp_bar/SG); Kv = 0.865 Cv (IEC 60534-1)
  • SI Q in m³/s, Δp in Pa; default SG=1 (water); not gas, not choked
  • Not a venturi, not an orifice, not Q=Av, not Darcy, not minor-loss K

Sources

Standards and references supporting this tool specification. Methods are listed separately — they are algorithms, not bibliographic sources.

Verification disclosure

Aggregate outcomes, scope and artifact commitments are public. Complete test inputs, expected values, execution records and oracle infrastructure are retained privately. This summary does not independently reproduce the full verification run.