Home Developers Evidence physics.fluid.side_weir

Public evidence

physics.fluid.side_weir

Machine-checked verification for calculation version 1.0.0 · tier engine_tested

CVP status

CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance · Borghei 1999 side weir Q=(2/3) Cd L √(2g) (y1−p)^{3/2} with Cd=0.71−0.41 Fr₁−0.22(p/y1), + O3 mpmath tabulated Q.

Not frontal/ogee/sluice. O3 tabulated vectors only.

Declared partition coverage
PASS · 5/5 declared partitions (flow, alias, awkward, v1, invalid-domain)
Versions
Calculation 1.0.0 · CVP protocol 1.0.0-proposed · Evidence 2026-10-28.meta-metrics-v2
Verification revision
2026-10-28.meta-metrics-v2 · 1/1 property · digest 05f62a7a5c60

Verification

Legacy regression suite: 6/6 calculation tests · Production surface contract 6/6

Three distinct suites: educational examples on the calculator page, this legacy regression count (6/6 golden + boundary), and the CVP verification suite below. They are not the same number. Property, metamorphic, round-trip, O3, and interface statuses/checks are recorded in the CVP Manifest . SKIP (0/0) means that suite has no published vectors.

    This calculator CURRENT · Public schema 1.0.0 matches · Semantic contract ✓ · Production attested · Public/cache ✓ · Origin ✓

CVP verification suite

Protocol checks from the Evidence Manifest. Distinct from the legacy regression suite above. Verification revision 2026-10-28.meta-metrics-v2. Calculation version 1.0.0. CVP 1.0.0-proposed. 4/4 golden · 1/1 CVP boundary · 3/3 invalid · 1/1 property · 1/1 metamorphic · 8/8 O3 · 2/2 cross-interface · 6/6 CVP contract. digest 05f62a7a5c60. O2: Borghei 1999 side weir vs a separate-module identity (≤2 ULP). Not frontal thin-plate, not ogee Hd, not sluice, not Manning, and not Q=Av. ≤2 ULP vs O3 applies only to the published tabulated side-weir vectors. Not frontal thin-plate, not ogee Hd, not sluice, not Manning, and not Q=Av.

  • Golden (oracle-backed) 4 / 4
  • CVP boundary 1 / 1
  • Invalid input 3 / 3
  • Property 1 / 1
  • Metamorphic 1 / 1
  • O3 high-precision 8 / 8
  • Cross-interface 2 / 2
  • CVP contract 6 / 6
  • Interfaces PASS · UI (SSR) / REST / MCP
  • Interface claim ui-ssr is query-result HTML, not a live browser session. Error-path engine·REST·MCP 1/1 (status, code, calculation_version). SSR compared on URL-canonical requested calculations; empty query is idle (not an error) and JSON-typed object/array inputs are REST/MCP-only.
  • Verified scope Borghei 1999 side weir Q=(2/3) Cd L √(2g) (y1−p)^{3/2} with Cd=0.71−0.41 Fr₁−0.22(p/y1), + O3 mpmath tabulated Q.
  • Assurance Engineering
  • Deferred Not frontal thin-plate given Cd, not ogee Hd, not sluice, not Manning, not submerged y2, not Q=Av.
  • release artifacts aligned PASS
  • schema output required declared PASS
  • schema valid input executes PASS
  • engine success output validates schema PASS
  • schema rejects incomplete input PASS
  • rest success payload validates schema PASS

Fingerprint sha256:ac4201768c6839ddd256cfe0fd33a639fb3acf8b69a5d6379003b5a5fee21804

Input schema sha256:029d0480ebbc750a983b5fc05500bfadb6e4148f3688b42f8e01a7114fdffeb5 · Output schema sha256:51594d0e6c8fa928d2a11ecf5efa96036a11d18ce05ffdfdf1e9fd58af76e7e5 · Build-time SHA-256 digests prove published artifacts agree with each other (release_integrity.scope=workspace). Production attestation GETs canonical URLs twice (public/cached view and origin), including Capability HTML, via npm run attest:production --write (published at /.well-known/calculatorx-production-attestation.json) and fails if the public Capability page advertises a different calculation_version. This is artifact consistency, not an independent immutable release log.

Build & scope

Engine identity and declared limitations.

Tool
side-weir
Engine
side-weir
Engine build
2026-09-24
Evidence core
2026-09-24T02:12:38.088Z
Rendered
2026-11-10T05:18:41.979Z
Last reviewed
—

Assumptions

  • Borghei 1999 sharp-crested side weir: Q=(2/3) C_d L √(2g) (y1−p)^{3/2}; C_d=0.71−0.41 Fr₁−0.22(p/y1); SI B, L, y1, p, Q1, Q; C_d is reported
  • Rectangular channel; subcritical Fr₁∈[0.1, 0.9]; p/y1∈[0.1, 0.9]; y1>p; free lateral overflow; De Marchi-type C_d, not a given frontal C_d
  • Not thin-plate frontal weir, not ogee Hd, not sluice a b √(2g y1), not Manning n, not Q=Av, not submerged y2

Limitations

  • Borghei 1999 sharp-crested side weir: Q=(2/3) C_d L √(2g) (y1−p)^{3/2}; C_d=0.71−0.41 Fr₁−0.22(p/y1); SI B, L, y1, p, Q1, Q; C_d is reported
  • Rectangular channel; subcritical Fr₁∈[0.1, 0.9]; p/y1∈[0.1, 0.9]; y1>p; free lateral overflow; De Marchi-type C_d, not a given frontal C_d
  • Not thin-plate frontal weir, not ogee Hd, not sluice a b √(2g y1), not Manning n, not Q=Av, not submerged y2

Sources

Standards and references supporting this tool specification. Methods are listed separately — they are algorithms, not bibliographic sources.

Verification disclosure

Aggregate outcomes, scope and artifact commitments are public. Complete test inputs, expected values, execution records and oracle infrastructure are retained privately. This summary does not independently reproduce the full verification run.