Home Developers Evidence physics.fluid.iso_orifice

Public evidence

physics.fluid.iso_orifice

Machine-checked verification for calculation version 1.0.0 · tier engine_tested

CVP status

CVP VERIFIED · CVP protocol 1.0.0-proposed · Engineering assurance · Q = C E A2 √(2Δp/ρ) with Reader–Harris/Gallagher C from β, Re_D, tapping; plus pressure and coefficient solves; + O3 mpmath tabulated discharge.

Not tank Cd. O3 tabulated vectors only.

Declared partition coverage
PASS · 5/5 declared partitions (flow, solve, alias, awkward, invalid-domain)
Versions
Calculation 1.0.0 · CVP protocol 1.0.0-proposed · Evidence 2026-09-27.o2-o3.v3
Verification revision
2026-09-27.o2-o3.v3 · 1/1 property · digest 3dcf46a2b2a6

Verification

Legacy regression suite: 6/6 calculation tests · Production surface contract 6/6

Three distinct suites: educational examples on the calculator page, this legacy regression count (6/6 golden + boundary), and the CVP verification suite below. They are not the same number. Property, metamorphic, round-trip, O3, and interface statuses/checks are recorded in the CVP Manifest . SKIP (0/0) means that suite has no published vectors.

    This calculator CURRENT · Public schema 1.0.0 matches · Semantic contract ✓ · Production attested · Public/cache ✓ · Origin ✓

CVP verification suite

Protocol checks from the Evidence Manifest. Distinct from the legacy regression suite above. Verification revision 2026-09-27.o2-o3.v3. Calculation version 1.0.0. CVP 1.0.0-proposed. 4/4 golden · 1/1 CVP boundary · 2/2 invalid · 1/1 property · 1/1 metamorphic · 8/8 O3 · 2/2 cross-interface · 6/6 CVP contract. digest 3dcf46a2b2a6. O2: ISO 5167-2 orifice Q=C E A2 √(2Δp/ρ), Reader–Harris/Gallagher C from β, Re_D, tapping vs a separate-module identity (≤2 ULP). Not tank C_d√(2gH), not given C_d, not ISA 1932, not venturi, not Q=Av, and not Darcy. ≤2 ULP vs O3 applies only to the published tabulated ISO-orifice vectors. Not tank C_d, not given C_d, not ISA 1932, not venturi, and not Q=Av.

  • Golden (oracle-backed) 4 / 4
  • CVP boundary 1 / 1
  • Invalid input 2 / 2
  • Property 1 / 1
  • Metamorphic 1 / 1
  • O3 high-precision 8 / 8
  • Cross-interface 2 / 2
  • CVP contract 6 / 6
  • Interfaces PASS · UI (SSR) / REST / MCP
  • Interface claim ui-ssr is query-result HTML, not a live browser session. Error-path engine·REST·MCP 1/1 (status, code, calculation_version). SSR compared on URL-canonical requested calculations; empty query is idle (not an error) and JSON-typed object/array inputs are REST/MCP-only.
  • Verified scope Q = C E A2 √(2Δp/ρ) with Reader–Harris/Gallagher C from β, Re_D, tapping; plus pressure and coefficient solves; + O3 mpmath tabulated discharge.
  • Assurance Engineering
  • Deferred Not tank C_d√(2gH), not given C_d, not ISA 1932, not venturi, not Q=Av, not Darcy, not D-D/2, not compressible ε.
  • release artifacts aligned PASS
  • schema output required declared PASS
  • schema valid input executes PASS
  • engine success output validates schema PASS
  • schema rejects incomplete input PASS
  • rest success payload validates schema PASS

Fingerprint sha256:896b2a670548bb36457bcb05d486e845e37d55e5f855be31c43faab028a200ee

Input schema sha256:c9462a4c1c1376534bbaf2cdbd8f8ec817236e1cd273f3ca8fa15ce7de8d8b74 · Output schema sha256:dacf3ff824d8880071f305497bb66908c4a2ab53df0e3ee608c512df9dab4336 · Build-time SHA-256 digests prove published artifacts agree with each other (release_integrity.scope=workspace). Production attestation GETs canonical URLs twice (public/cached view and origin), including Capability HTML, via npm run attest:production --write (published at /.well-known/calculatorx-production-attestation.json) and fails if the public Capability page advertises a different calculation_version. This is artifact consistency, not an independent immutable release log.

Build & scope

Engine identity and declared limitations.

Tool
iso-orifice
Engine
iso-orifice
Engine build
2026-09-24
Evidence core
2026-09-24T02:12:38.088Z
Rendered
2026-11-10T05:18:41.966Z
Last reviewed
—

Assumptions

  • ISO 5167-2 orifice plate: Q = C E A2 √(2Δp/ρ); Reader–Harris/Gallagher C from β, Re_D, and tapping; incompressible ε=1; C is reported, not an input
  • Corner tappings default (L1=L2′=0); flange L1=L2′=25.4 mm/D; β∈[0.10,0.75]; D∈[50 mm,1000 mm]; d≥12.5 mm; Re_D≥5000 (β≤0.56) or 16000 β² (β>0.56)
  • Not tank orifice C_d A √(2gH), not given C_d=0.61, not ISA 1932 nozzle, not venturi C_d=0.98, not Q=Av, not Darcy f, not D-D/2 tappings, not compressible ε

Limitations

  • ISO 5167-2 orifice plate: Q = C E A2 √(2Δp/ρ); Reader–Harris/Gallagher C from β, Re_D, and tapping; incompressible ε=1; C is reported, not an input
  • Corner tappings default (L1=L2′=0); flange L1=L2′=25.4 mm/D; β∈[0.10,0.75]; D∈[50 mm,1000 mm]; d≥12.5 mm; Re_D≥5000 (β≤0.56) or 16000 β² (β>0.56)
  • Not tank orifice C_d A √(2gH), not given C_d=0.61, not ISA 1932 nozzle, not venturi C_d=0.98, not Q=Av, not Darcy f, not D-D/2 tappings, not compressible ε

Sources

Standards and references supporting this tool specification. Methods are listed separately — they are algorithms, not bibliographic sources.

Verification disclosure

Aggregate outcomes, scope and artifact commitments are public. Complete test inputs, expected values, execution records and oracle infrastructure are retained privately. This summary does not independently reproduce the full verification run.