  "capability_id": "electrical.apparent_power",
  "tool_id": "amps-to-va",
  "engine": "amps-va",
  "calculation_version": "1.4.3",
  "generated_at": "2026-11-10T05:18:41.661Z",
  "engine_build": "2026-09-10",
  "test_count": 36,
  "passed": 36,
  "failed": 0,
  "tests_summary": {
    "golden": {
      "passed": 9,
      "total": 9
    },
    "boundary": {
      "passed": 13,
      "total": 13
    },
    "property": {
      "passed": 14,
      "total": 14
    }
  },
  "engine_tested": true,
  "expert_reviewed": false,
  "internally_reviewed": false,
  "review_kind": null,
  "source_checked": true,
  "reviewed_by": null,
  "reviewer_role": null,
  "last_reviewed": null,
  "expert_review": {
    "status": "optional_not_performed",
    "reviewer": null,
    "scope": [
      "formula",
      "input semantics",
      "assumptions",
      "limitations",
      "sources",
      "tests"
    ],
    "note": "Domain expert review is optional under CVP (CVP-EXP-01). Absence does not block CVP Verified. See Review policy for supplemental domain assurance."
  },
  "internal_review": {
    "status": "not_applicable",
    "reviewer": null
  },
  "page": "https://www.calculatorx.com/calc/electric/amps-to-va",
  "api": "https://www.calculatorx.com/api/v1/calc/amps-to-va",
  "schema_input": "https://www.calculatorx.com/schemas/electrical.apparent_power.input.json",
  "schema_output": "https://www.calculatorx.com/schemas/electrical.apparent_power.output.json",
  "assumptions": [
    "AC steady-state with RMS voltage and current magnitudes.",
    "Three-phase mode is balanced sinusoidal AC using line-to-line RMS voltage, where V_LL = √3 V_LN and line currents are equal. IEEE 1459 covers a wider set of conditions; this calculator does not.",
    "Total power factor λ is not applied to VA/kVA results."
  ],
  "limitations": [
    "Not for DC systems",
    "Not for unbalanced or nonsinusoidal three-phase; √3 formula assumes balanced sinusoidal V_LL = √3 V_LN and equal line currents",
    "Not for line-to-neutral three-phase mode",
    "Not for equipment protection or conductor sizing",
    "When power_factor is supplied, REST/MCP include derived.estimated_real_power; omitted when λ is absent"
  ],
  "boundary_conditions": [
    "Missing or non-positive voltage returns an error (UI and API); never a fake 0 A / 0 VA",
    "Power factor outside [0, 1] is rejected when provided; not silently ignored. λ=0 is accepted (P_est=0 when S>0).",
    "Negative primary (current or VA) is rejected",
    "Overflow to Infinity or NaN is rejected as NON_FINITE_RESULT; never returned as a success result"
  ],
  "sources": [
    {
      "title": "IEC 60050 — International Electrotechnical Vocabulary",
      "section": "Apparent power (IEV 131-11-41)",
      "url": "https://www.electropedia.org/iev/iev.nsf/display?openform&ievref=131-11-41",
      "supports": "S = U × I definition of apparent power; unit volt-ampere (VA)",
      "kind": "standard",
      "accessed": "2026-09-04",
      "clause": "IEV 131-11-41"
    },
    {
      "title": "IEC 60050 — International Electrotechnical Vocabulary",
      "section": "Power factor (IEV 131-11-46)",
      "url": "https://www.electropedia.org/iev/iev.nsf/display?openform&ievref=131-11-46",
      "supports": "λ = |P| / S, so λ = 0 when P = 0 and S > 0; optional page/API estimate P_est = S × λ_entered uses this definition",
      "kind": "standard",
      "accessed": "2026-09-04",
      "clause": "IEV 131-11-46"
    },
    {
      "title": "IEEE Std 1459-2025",
      "section": "Definitions for electric power measurement under sinusoidal, nonsinusoidal, balanced, or unbalanced conditions",
      "url": "https://standards.ieee.org/ieee/1459/7578/",
      "supports": "IEEE 1459 covers sinusoidal, nonsinusoidal, balanced, and unbalanced conditions. This calculator implements only the balanced sinusoidal three-phase model S = √3 × V_L-L × I_L (V_LL = √3 V_LN, equal line currents).",
      "kind": "standard",
      "accessed": "2026-09-04",
      "publisher": "IEEE",
      "published": "2025-05-16",
      "errata_checked": true
    },
    {
      "title": "BIPM SI Brochure (9th edition, version 4.01)",
      "section": "SI base and derived units for ampere, volt, and power",
      "url": "https://www.bipm.org/en/publications/si-brochure",
      "supports": "V, A, W, and VA unit relationships",
      "kind": "reference",
      "accessed": "2026-09-04",
      "published": "2026-06",
      "doi": "https://doi.org/10.59161/AUEZ1291"
    }
  ],
  "methods": [],
  "fingerprint": "sha256:8f1fe71ef5ac163067373cca83fd06606a09cf26222e4f7549938786262e71d7",
  "tier": "engine_tested",
  "verification": {
    "tests": {
      "passed": 36,
      "total": 36,
      "golden": 9,
      "boundary": 13,
      "property": 14
    },
    "contract_checks": {
      "passed": 6,
      "total": 6
    }
  },
  "evidence_core_generated_at": "2026-09-10T22:48:17.762Z",
  "rendered_at": "2026-11-10T05:18:41.661Z",
  "release_integrity": {
    "status": "verified",
    "scope": "workspace",
    "production_attestation_required": true,
    "calculation_version": "1.4.3",
    "artifacts": {
      "engine": "1.4.3",
      "page": "1.4.3",
      "capability": "1.4.3",
      "evidence": "1.4.3",
      "input_schema": "1.4.3",
      "output_schema": "1.4.3",
      "mcp_contract": "1.4.3"
    },
    "digests": {
      "input_schema_sha256": "5bf23cb0b374dc943d075d420a742cbbfabfe8dd5b7f4a26a608ec186c0b9835",
      "output_schema_sha256": "550be97c601f18e5c860c9a6aaf3d5f117474eda14f4121568ae369861f1b19c",
      "evidence_sha256": "5a2953f6e477fe8209fcf7c24d5e04f38452fda1a88096f95fd879301bc6aec7",
      "evidence_core_sha256": "5a2953f6e477fe8209fcf7c24d5e04f38452fda1a88096f95fd879301bc6aec7",
      "capability_sha256": "759a302daeeb7c5d5a1fcf4cd35dde92fe57a341d4c24e8fc570487a7494f20e",
      "engine_sha256": "c6ebd8436f08b413e1ac6317b2d48550f2e6639a90dff254244e3aa562158b8d",
      "mcp_contract_sha256": "eb3e39ad4a95ed263415b4932f185d5edfe00a2403267b7c5ed5f718d1ff6da3"
    },
    "contract_checks": {
      "total": 6,
      "passed": 6,
      "failed": 0,
      "items": [
        {
          "id": "release-artifacts-aligned",
          "status": "pass",
          "detail": "1.4.3"
        },
        {
          "id": "schema-output-required-declared",
          "status": "pass"
        },
        {
          "id": "schema-valid-input-executes",
          "status": "pass"
        },
        {
          "id": "engine-success-output-validates-schema",
          "status": "pass"
        },
        {
          "id": "schema-rejects-incomplete-input",
          "status": "pass"
        },
        {
          "id": "rest-success-payload-validates-schema",
          "status": "pass"
        }
      ]
    },
    "report": "https://www.calculatorx.com/.well-known/calculatorx-release-integrity.json"
  },
  "tests": [],
  "disclosure": {
    "policy": "calculatorx-public-evidence-v1",
    "full_validation": "private",
    "representation": "summary"
  }
}